IS Vs Non-IS Cables

In Instrumentation, cables are broadly classified as IS (Intrinsically Safe) and Non-IS (Non-Intrinsically Safe) cables based on the type of electrical circuits they are connected to.


1. IS Cables (Intrinsically Safe Cables)

IS cables are used for intrinsically safe circuits, where the electrical energy is limited to prevent sparks or heat capable of igniting hazardous gases or vapors.

These are commonly used in hazardous areas such as:

  • Oil & Gas plants
  • Refineries
  • Chemical plants
  • Offshore platforms

Purpose

The purpose of an IS system is to ensure that even under fault conditions, the circuit cannot produce enough energy to cause an explosion.

Typical Applications

  • Pressure transmitters
  • Temperature transmitters
  • Gas detectors
  • Flow transmitters
  • Field instruments in hazardous zones

Identification

IS cables are usually identified by:

  • Light blue color outer sheath or marking
  • Blue cable tags/glands/junction boxes

(Blue color is an international practice for IS systems.)

Characteristics

  • Connected through:
    • IS barriers
    • Galvanic isolators
  • Low voltage and low current circuits
  • Require segregation from non-IS cables

Installation Requirements

IS cables must:

  • Be routed separately from non-IS cables
  • Maintain minimum separation distance
  • Use dedicated cable trays or partitions
  • Follow hazardous area standards

Relevant Standards

  • IEC 60079
  • NFPA
  • ATEX standards

2. Non-IS Cables (Non-Intrinsically Safe Cables)

Non-IS cables are used for normal electrical/instrumentation circuits where energy limitation is not provided.

These cables can carry enough electrical energy to ignite hazardous atmospheres if a fault occurs.

Typical Applications

  • Control valves
  • Solenoids
  • Motors
  • Marshalling signals
  • Power supplies
  • Non-hazardous area instruments

Characteristics

  • Normal instrumentation/control cables
  • No intrinsic safety barriers required
  • Higher voltage/current possible

Identification

Non-IS cables usually:

  • Do not have blue color identification
  • Use standard cable markings

Key Difference Between IS and Non-IS Cables

FeatureIS CableNon-IS Cable
Safety ConceptEnergy limitedNormal energy
Hazardous Area UseYesLimited/with protection
Color IdentificationLight BlueStandard colors
Requires IS BarrierYesNo
Explosion ProtectionIntrinsic SafetyOther protection methods
Segregation RequiredStrictly requiredNormal routing

Important Practical Point

In projects such as:

  • DCS
  • ESD
  • F&G systems

IS and non-IS cables must never be mixed randomly in the same marshalling/JB/tray without proper segregation.

Typical site practices include:

  • Separate cable trays
  • Metallic partitions
  • Minimum spacing
  • Separate gland plates

Simple Example

IS Circuit

Pressure Transmitter → IS Barrier → DCS AI Card

Non-IS Circuit

Control Valve Solenoid → Marshalling Cabinet → DO Card


Common Cable Types Used

IS Instrument Cable

  • 1 Pair / 2 Pair shielded twisted pair
  • Overall shield
  • Blue sheath

Non-IS Instrument Cable

  • Multi-pair instrument cable
  • Control cable
  • Power cable

Easy Way to Remember

  • IS = Safe energy level
  • Non-IS = Normal energy level

Or:

IS prevents explosion by limiting energy.
Non-IS uses other protection methods or normal installation practices.